• DocumentCode
    649272
  • Title

    Micro-fabrication of an absolute flow calorimeter for DC to RF power measurement

  • Author

    Neji, Bilel ; Jing Xu ; Titus, A.H. ; Meltzer, Joel

  • Author_Institution
    Dept. of Electr. Eng., SUNY - Univ. at Buffalo, Buffalo, NY, USA
  • fYear
    2013
  • fDate
    4-7 Aug. 2013
  • Firstpage
    701
  • Lastpage
    704
  • Abstract
    Micro-fabricated calorimeters have been extensively used for determination of thermo chemical values and reaction kinetic studies. However, micro-fabricated calorimeters as power sensors have been mostly unexplored. In this context, miniaturization of an absolute flow calorimeter capable of measuring DC to RF power is proposed. In this paper, a micro-fabricated flow calorimeter is demonstrated and several initial test results, such as DC power measurement and the impact of flow rate on heat transferring, are reported. The obtained results will play an important role in performing RF power measurements in the future.
  • Keywords
    calorimeters; flow sensors; heat transfer; microsensors; power measurement; DC power measurement; DC to RF power measurement; absolute flow calorimeter; flow rate; heat transfer; microfabricated flow calorimeter; power sensor; reaction kinetic study; thermochemical value;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Circuits and Systems (MWSCAS), 2013 IEEE 56th International Midwest Symposium on
  • Conference_Location
    Columbus, OH
  • ISSN
    1548-3746
  • Type

    conf

  • DOI
    10.1109/MWSCAS.2013.6674745
  • Filename
    6674745