Abstract :
We describe a one-port de-embedding technique suitable for the quasi-optical characterization of terahertz integrated components at frequencies beyond the operational range of most vector network analyzers. This technique is also suitable when the manufacturing of precision terminations to sufficiently fine tolerances for the application of a TRL de-embedding technique is not possible. The technique is based on vector reflection measurements of a series of easily realizable test pieces. A theoretical analysis is presented for the precision of the technique when implemented using a quasi-optical null-balanced bridge reflectometer. The analysis takes into account quantization effects in the linear and angular encoders associated with the balancing procedure, as well as source power and detector noise equivalent power. The precision in measuring waveguide characteristic impedance and attenuation using this de-embedding technique is further analyzed after taking into account changes in the power coupled due to axial, rotational, and lateral alignment errors between the device under test and the instruments´ test port. The analysis is based on the propagation of errors after assuming imperfect coupling of two fundamental Gaussian beams. The required precision in repositioning the samples at the instruments´ test-port is discussed. Quasi-optical measurements using the de-embedding process for a WR-8 adjustable precision short at 125 GHz are presented. The de-embedding methodology may be extended to allow the determination of S-parameters of arbitrary two-port junctions. The measurement technique proposed should prove most useful above 325 GHz where there is a lack of measurement standards.
Keywords :
S-parameters; measurement errors; reflectometers; terahertz wave devices; Gaussian beams; S-parameters; TRL de-embedding technique; account quantization effects; axial alignment errors; detector noise equivalent power; device under test; fine tolerances; lateral alignment errors; measurement standards; one-port de-embedding technique; quasi-optical characterization; quasi-optical null-balanced bridge reflectometer; realizable test pieces; rotational alignment errors; source power; terahertz integrated components; vector network analyzers; vector reflection measurements; waveguide characteristic impedance; Feeds; Instruments; Optical waveguides; Propagation constant; Reflection; Reflectivity; Vectors; De-embedding; S-parameters; integrated component characterization; null-balance quasi-optical reflectometer;
Journal_Title :
Sensors Journal, IEEE
DOI :
10.1109/JSEN.2012.2226713