Title :
Analysis of losses in the core of an electrodeless fluorescent lamp
Author :
da Silva, M.F. ; Schlittler, M.E. ; Fraytag, J. ; Chagas, N.B. ; Seidel, A.R. ; do Prado, Ricardo N.
Author_Institution :
Fed. Univ. of Santa Maria - UFSM, Santa Maria, Brazil
Abstract :
An investigation of magnetic core losses of an electrodeless fluorescent lamp is presented in this paper. These losses can be divided into two different kinds: static, which is related to hysteresis effects, and dynamical, associated to parasitic effects. Experimental results (at 25° C) demonstrate that the total losses, in nominal condition point, are approximately 3.18 W, what represent 3.18% of the power supplied to the lamp. In this same point, the static losses are approximately 1.31 W and the dynamic losses about 1.87 W. Based on this, the static losses represent about 41% of total loss related to the magnetic core while dynamical losses represents 59% of total loss.
Keywords :
eddy current losses; fluorescent lamps; magnetic cores; magnetic hysteresis; magnetic leakage; dynamic loss; electrodeless fluorescent lamp; hysteresis effect; magnetic core loss; nominal condition point; parasitic effect; static loss; temperature 25 degC; Energy loss; Polynomials; Saturation magnetization; Toroidal magnetic fields; Electrodeless Fluorescent Lamps; Hysteresis and Parasitic Effects; Magnetic Core Losses;
Conference_Titel :
Industry Applications Society Annual Meeting, 2013 IEEE
Conference_Location :
Lake Buena Vista, FL
DOI :
10.1109/IAS.2013.6682542