  • Abstract
    This study deals with the safety operation of AC resistance spot welding (RSW) system. The input of the RSW system is the firing angle of the silicon-controlled rectifier (SCR) during each control cycle. Wrongly choosing a firing angle may induce disastrous consequence. The range of firing angle depends on the system´s power factor angle; the relation between the firing angle, power factor angle and conduction angle is highly non-linear. After comparing three methods, a simple mathematical model is proposed in this study to facilitate the online calculation of the power factor angle and selection of the proper firing angle, so that the safety operation of RSW system can be guaranteed. In this condition, the RSW machine can work at the machine´s the most capacity, the calculated value of power factor angle should be the lowest limit for actual selected firing angle of SCR. Finally, experimental results confirmed the effectiveness of the proposed mathematical model.
  • Keywords
    power factor; safety; spot welding; thyristors; AC resistance spot welding system; RSW system; SCR; conduction angle; control cycle; firing angle; mathematical model; safety operation; silicon-controlled rectifier; system power factor angle;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IET
  • Publisher
    iet
  • ISSN
    1755-4535
  • Type

    jour

  • DOI
    10.1049/iet-pel.2013.0094
  • Filename
    6715879