DocumentCode :
656264
Title :
An error current tracking control method of three-level active power filter
Author :
Zhang Chenyu ; Mei Jun ; Zheng Jianyong
Author_Institution :
Coll. of Electr. Eng., Southeast Univ., Nanjing, China
fYear :
2013
fDate :
3-6 Nov. 2013
Firstpage :
58
Lastpage :
62
Abstract :
In order to track the error current of three-level active filter more effectively, this paper presents a hysteresis current control method based on voltage space vector. Based on the conventional method, the selection of the resultant vector is no longer confined to a small sector the reference voltage belongs to. It finds out the optimal switching state through optimization in a large sector, which makes the track of error current by resultant vector more effective. From the perspective of control strategy, three-level active power filter based on LCL-type output filter using this control method has better tracking performance. Finally, the simulation and experiment validate the effectiveness of the proposed method.
Keywords :
active filters; electric current control; hysteresis; optimisation; power filters; LCL-type output filter; error current tracking control method; hysteresis current control method; optimal switching state; three-level active power filter; voltage space vector; Hysteresis; Indexes; Linear systems; Vectors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Future Energy Electronics Conference (IFEEC), 2013 1st International
Conference_Location :
Tainan
Print_ISBN :
978-1-4799-0071-8
Type :
conf
DOI :
10.1109/IFEEC.2013.6687479
Filename :
6687479
Link To Document :