    Development of a small animal SPECT imager with LYSO scintillator arrays and PSPMTs

  • Author

    Qiushi Zhang ; Suying Li ; Zhaoheng Xie ; Yanye Lu ; Kun Yang ; Qiushi Ren

  • Author_Institution
    Inst. for Drug & Instrum. Control of PLA, Beijing, China
  • fYear
    2013
  • fDate
    23-25 Oct. 2013
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    We describe a small animal SPECT imager based on scintillation crystal arrays and position sensitive photomultiplier tube (PSPMT). This SPECT detector consists of a cerium doped lutetium-yttrium oxyorthosilicate (LYSO) scintillation crystal (22 × 22 pixel array, 2 mm × 2 mm × 3 mm pixel size), a H8500c PSPMT (Hamamatsu Photonics Co., Ltd., Shizuoka Prefecture, Japan), and a parallel hole collimator (Nuclear Fields Pty. Ltd, St. Marys, Australia). The detector design, electronic setup and image correction method are presented. Conical phantom study and animal experiment (BALB/C male nude mice, 16 week, 20g) were performed for the uniformity correction evaluation and imaging performance test respectively. The preliminary results demonstrate that this SPECT imager can achieve the small animal whole body imaging effectively and thus be one of the modalities of our future multimodality imaging system. The feasibility that LYSO crystal can substitute NaI(TI) for SPECT imager development is also validated..
  • Keywords
    collimators; phantoms; photomultipliers; position sensitive particle detectors; scintillation counters; single photon emission computed tomography; BALB/C male nude mice; H8500c PSPMT; LYSO crystal; LYSO scintillator arrays; NaI(TI) crystal; SPECT detector; SPECT imager development; cerium doped lutetium-yttrium oxyorthosilicate scintillation crystal; conical phantom study; detector design; electronic setup; image correction method; imaging performance test; multimodality imaging system; parallel hole collimator; position sensitive photomultiplier tube; scintillation crystal arrays; small animal SPECT imager; small animal whole body imaging; uniformity correction evaluation; Crystals; Detectors; Image reconstruction; Mice; Single photon emission computed tomography; 99mTc-3PRG2; animal imaging; image correction; single photon emission computed tomography; tumor;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Engineering International Conference (BMEiCON), 2013 6th
  • Conference_Location
    Amphur Muang
  • Print_ISBN
    978-1-4799-1466-1
  • Type

    conf

  • DOI
    10.1109/BMEiCon.2013.6687648
  • Filename
    6687648