DocumentCode :
656935
Title :
High sensitivity CMOS portable biosensor with flexible microfluidic integration
Author :
Goktas, Hasan ; Zaghloul, Mona E.
Author_Institution :
Electr. & Comput. Eng., George Washington Univ., Washington, DC, USA
fYear :
2013
fDate :
3-6 Nov. 2013
Firstpage :
1
Lastpage :
4
Abstract :
In this work, a portable biosensor that has 60% effective surface area on the chip with 1fg sensitivity by using novel array configuration is designed, and sent for fabrication. High frequency shift, quality factor, capacitance ratio, and small response time during the AC actuation are the critical parameters for the biosensor design. By using a beam structure in contrast to the more common cantilever, the effective surface area increases from 41% to 71%. Flexible microfluidic channels are integrated with the CMOS chip to deliver the biomaterial and are used for the packaging.
Keywords :
CMOS integrated circuits; biosensors; microfluidics; microsensors; sensor arrays; AC actuation; CMOS portable biosensor; array configuration; biomaterial delivery; flexible microfluidic integration; high frequency shift biosensor; high quality factor biosensor; Biosensors; CMOS integrated circuits; Capacitance; Microfluidics; Q-factor; Sensitivity; Structural beams;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
SENSORS, 2013 IEEE
Conference_Location :
Baltimore, MD
ISSN :
1930-0395
Type :
conf
DOI :
10.1109/ICSENS.2013.6688202
Filename :
6688202
Link To Document :
بازگشت