• DocumentCode
    662274
  • Title

    Coherent time reversal minimum variance beamforming for the localization of tissue malignancies in dense breast phantoms

  • Author

    Hossain, Md Delowar ; Mohan, Ananda Sanagavarapu

  • Author_Institution
    Fac. of Eng. & IT, Center for Health Technol., Univ. of Technol., Sydney, Sydney, NSW, Australia
  • fYear
    2013
  • fDate
    5-8 Nov. 2013
  • Firstpage
    377
  • Lastpage
    379
  • Abstract
    The time reversal (TR) based minimum variance beamforming, both the standard capon beamforming (SCB) and robust capon beamforming (RCB) techniques for microwave imaging of breast for early stage breast cancer detection is considered in this paper. The performance of coherent signal subspace processing for TR-SCB and TR-RCB techniques is investigated. We have used anatomically realistic numerical breast phantoms in FDTD simulations. We consider 2D sagittal slice of the breast phantom in 2D FDTD simulation. Our simulation results indicate that coherent signal subspace processing significantly improves the performance of TR based minimum variance beamforming techniques.
  • Keywords
    array signal processing; cancer; finite difference time-domain analysis; medical signal processing; microwave imaging; phantoms; 2D sagittal slice; FDTD simulation; RCB technique; SCB technique; breast cancer detection; coherent time reversal minimum variance beamforming; dense breast phantoms; microwave imaging; robust capon beamforming; standard capon beamforming; tissue malignancies localization; Array signal processing; Breast cancer; Microwave imaging; Microwave theory and techniques; Phantoms; Time reversal; breast cancer; coherent signal subspace; microwave imaging; robust Capon beam forming;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference Proceedings (APMC), 2013 Asia-Pacific
  • Conference_Location
    Seoul
  • Type

    conf

  • DOI
    10.1109/APMC.2013.6695152
  • Filename