Abstract
This paper presents a method for the simultaneous measurement of multiple impulse responses with a single receiver. For UWB measurements multiple impulse responses are usually determined at different times. Here, an approach is investigated, which employs preferred pairs of maximum length sequences (m-sequences) having a low cross correlation function. Therefore, a measurement system is built capable of generating and sampling two m-sequences at 400Mb/s. Since the m-sequences are not decoupled perfectly, a method for the error correction is shown.
Keywords
correlation methods; microwave measurement; radio receivers; signal sampling; UWB measurement; bit rate 400 Mbit/s; cross correlation function; error correction; m-sequence; maximum length sequence; multiple impulse response measurement; single receiver; Correlation; Error correction; Frequency measurement; Materials; Radar applications; Receivers; Time-domain analysis; UWB; m-sequence; maximum length sequence; time domain measurements;