DocumentCode :
665355
Title :
MEMS packaging reliability assessment: Last development in the field of residual gas analysis tests
Author :
Charvet, Pierre-Louis ; Nicolas, Pierre ; Bloch, D. ; Savornin, B.
Author_Institution :
Characterization & Reliability of Components Lab., CEA, Grenoble, France
fYear :
2013
fDate :
9-12 Sept. 2013
Firstpage :
1
Lastpage :
5
Abstract :
The reliability of MEMS sensors or actuators such as accelerometers, gyroscopes, resonators, RF switches, microbolometers... is critically dependent on the vacuum level and on the nature of the gaseous species present inside the MEMS cavity (~1mm3 or less, usually in the 10-2-10-3 mbar vacuum range after sealing by Wafer Level Packaging process. Although a lot of methods have been explored [1], the Residual Gas Analysis (RGA) method-however destructive - reveals to be an interesting method to determine the possible sources of gaseous species present in the MEMS cavity, in order to assess to which extent a given packaging technology is capable of maintaining the required environmental conditions all along the device lifetime. This paper introduces results recently achieved with a specific RGA test bench designed, developed and validated at the CEA-LETI to meet these requirements. This Ultra High Vacuum (UHV) RGA equipment operates under a residual background pressure level in the 10-10 mbar range and uses a quadrupolar mass spectrometer (QMS) for gas analysis. Experimental results confirm that the RGA technique is successfully used to identify the nature and proportions of gases trapped in cavities as small as 1 mm3 under a residual pressure lower than 10-2 mbar. Under favorable conditions and using UHV-compatible specific mechanical tools, it is possible to identify the sources of the various gases present inside the package by sequentially breaking under UHV spare parts of the device such as the bonding layer, the cap and the MEMS substrate. It also proves to be an interesting tool to study the degassing behavior of materials and their compatibility with the MEMS fabrication process steps.
Keywords :
chemical analysis; mass spectra; microactuators; microsensors; reliability; vacuum apparatus; wafer level packaging; MEMS actuators; MEMS cavity; MEMS fabrication process; MEMS packaging reliability assessment; MEMS sensor reliability; MEMS substrate; QMS; RF switches; RGA method; UHV-compatible specific mechanical tools; accelerometers; bonding layer; cap; device lifetime; gaseous species; gyroscopes; material degassing behavior; microbolometers; packaging technology; quadrupolar mass spectrometer; residual background pressure level; residual gas analysis tests; resonators; ultrahigh vacuum RGA equipment; vacuum level; wafer level packaging process; Cavity resonators; Electron tubes; Gases; Glass; Micromechanical devices; Packaging; MEMS; RGA; UHV; packaging; reliability; sealing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microelectronics Packaging Conference (EMPC) , 2013 European
Conference_Location :
Grenoble
Type :
conf
Filename :
6698679
Link To Document :
بازگشت