• DocumentCode
    665788
  • Title

    An active feedforward compensation for a current harmonics reduction in three-phase grid-connected inverters

  • Author

    Byong-Jun Park ; Ki-Young Choi ; Rae-Young Kim

  • Author_Institution
    Energy Electron. Control Syst. Lab., Hanyang Univ., Ansan, South Korea
  • fYear
    2013
  • fDate
    10-13 Nov. 2013
  • Firstpage
    400
  • Lastpage
    405
  • Abstract
    The paper discusses the influence of a grid impedance, especially for a leakage inductance of a grid side transformer. The grid impedance does not usually take into account during the design stage of the current controller. As a result, low order harmonics in the grid current are distorted. In this paper, the active feed-forward compensation method is proposed for the purpose of attenuating the current distortion. The proposed method can be applied to L filter as well as LCL filter. The effectiveness of the method is verified through various simulations and experiments based on a 1.5kW voltage source inverter prototype.
  • Keywords
    compensation; control system synthesis; electric current control; feedforward; invertors; power filters; L filter; LCL filter; active feedforward compensation method; current controller; current distortion; current harmonics reduction; design stage; grid impedance; grid side transformer; leakage inductance; power 1.5 kW; three-phase grid-connected inverters; voltage source inverter prototype; Impedance; Inverters; Resistance; Resonant frequency; Switches; Time-frequency analysis; Active feedforward; THD; harmonic compensation; low frequency transformer; low order harmonic; weak grid;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics Society, IECON 2013 - 39th Annual Conference of the IEEE
  • Conference_Location
    Vienna
  • ISSN
    1553-572X
  • Type

    conf

  • DOI
    10.1109/IECON.2013.6699169
  • Filename
    6699169