DocumentCode
669258
Title
A fast global variational bias field correction method for MR images
Author
Ivanovska, Tatyana ; Lei Wang ; Laqua, Rene ; Hegenscheid, Katrin ; Volzke, Henry ; Liebscher, Volkmar
Author_Institution
Ernst-Moritz-Arndt Univ., Greifswald, Germany
fYear
2013
fDate
4-6 Sept. 2013
Firstpage
667
Lastpage
671
Abstract
Magnetic resonance (MR) images are prone to inhomogeneity artefacts that hinder an efficient automatic segmentation. Existing correction methods are often dependent on initialization and computationally expensive. This paper proposes a novel variational approach for the simultaneous bias field correction and image segmentation together with its efficient implementation, which produces the global solution that does not depend on initializations. The method is compared against another recently proposed method in terms of speed, efficiency, and performance.
Keywords
biomedical MRI; image segmentation; medical image processing; MR images; automatic segmentation; global variational bias field correction method; image segmentation; inhomogeneity artefacts; magnetic resonance images; simultaneous bias field correction; variational approach; Biomedical imaging; Breast; Image segmentation; Level set; Minimization; Nonhomogeneous media; Signal processing algorithms;
fLanguage
English
Publisher
ieee
Conference_Titel
Image and Signal Processing and Analysis (ISPA), 2013 8th International Symposium on
Conference_Location
Trieste
Type
conf
DOI
10.1109/ISPA.2013.6703822
Filename
6703822
Link To Document