A MRI Rotary Phased Array Head Coil
Author :
Bing Keong Li ; Weber, E. ; Crozier, Stuart
Author_Institution :
Sch. of Inf. Technol. & Electr. Eng., Univ. of Queensland, Brisbane, QLD, Australia
Volume :
7
Issue :
4
fYear :
2013
fDate :
Aug. 2013
Firstpage :
548
Lastpage :
556
Abstract :
A new rotary phased array (RPA) head coil that can provide homogenous brain images comparable to volumetric radiofrequency coils is proposed for magnetic resonance brain imaging applications. The design of the RPA head coil is a departure from conventional circumferential array design method, as coil elements of the RPA head coil have a “paddle-like” structure consisting of a pair of main conductors located on opposite sides, inserted equi-angularly around and over the head. A prototype 2T receive-only 4-element RPA head coil was constructed and experimentally tested against a conventional receive-only 4-element phased array head coil and a commercial receive-only quadrature birdcage head coil. Homogenous phantom images acquired by the RPA head coil show that signal intensity deep at the center of the phantom was improved as compared to the conventional phased array head coil and this improvement allow the RPA head coil to acquire homogenous brain images similar to brain images acquired with the birdcage head coil. In addition, partial parallel imaging was used in conjunction with the RPA head coil to enable rapid imaging.
Keywords :
biomedical MRI; biomedical electronics; brain; coils; phantoms; prototypes; 2T receive-only 4-element RPA head coil; MRI rotary phased array head coil; RPA head coil design; coil element; conventional circumferential array design; conventional phased array head coil; homogenous brain image; homogenous phantom image; magnetic flux density 2 T; magnetic resonance brain imaging application; main conductor; paddle-like structure; partial parallel imaging; phantom center; prototype; rapid imaging; receive-only quadrature birdcage head coil; signal intensity; volumetric radiofrequency coil; Coils; Conductors; Head; Imaging; Inductors; Magnetic heads; Radiation detectors; Counter wound inductive decoupling; MRI phased array coil; rotary phased array coil; Brain; Head; Humans; Magnetic Resonance Imaging; Male; Phantoms, Imaging;
fLanguage :
English
Journal_Title :
Biomedical Circuits and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
1932-4545
Type :
jour
DOI :
10.1109/TBCAS.2012.2230173
Filename :
6469185
Link To Document :
بازگشت