    Multichannel foetal heartbeat detection by combining source cancellation with expectation-weighted estimation of fiducial points

  • Author

    Di Marco, Luigi Yuri ; Marzo, Asier ; Frangi, Alejandro

  • Author_Institution
    Center for Comput. Imaging & Simulation Technol. in Biomed. (CISTIB), Univ. of Sheffield, Sheffield, UK
  • fYear
    2013
  • fDate
    22-25 Sept. 2013
  • Firstpage
    329
  • Lastpage
    332
  • Abstract
    Noninvasive foetal heart rate (fHR) monitoring is important in detecting foetal distress and morbidity. In spite of the improvement achieved in recent years, the accuracy of non-invasive fHR monitors is not satisfactory. In this study a new method is presented with the goal of improving the accuracy of foetal heart beat detection from abdominal recordings of maternal ECG. A dataset of 75 four-channel abdominal ECG recordings (SetA) provided by Physionet Challenge 2013 was used for training. Maternal QRSs were detected and subtracted from notch-filtered (50 Hz) and high-pass filtered (4 Hz) abdominal ECGs. The residual ECG signal was further processed (1st derivative squared and low-pass filtered by moving-average). On the resulting signals, local peaks were searched using an expectation-weighted estimate of the “next” fiducial point (foetal QRS (fQRS)) based on a Gaussian distribution G(μ,σ) with μ indicating the most probable time distance of the “next” fiducial point. A grid search was used to determine (μ,σ) minimizing the standard deviation of the resulting estimated fQRS time series for each recording. The fQRS time series were submitted to Physionet Challenge 2013 Events 4 and 5. In Event 4 (published set of 100 recordings, SetB), a test fHR time series was built by Physionet´s Scoring System from fQRS annotations and matched to the reference. Scores were based on test vs. reference mismatches (lower scores indicate better performance). In Event 5 (also using SetB), the RR time series replaced fHR. According to Phase 1 official scores (14 June 2013) our algorithm scored 135.18 (7.11) in Event 4 (Event 5), corresponding to the 10th (9th) position in the ranking. The reference algorithm provided by Physionet scored 3258.56 (102.75). The proposed method substantially improved the foetal heart beat detection accuracy with respect to the reference algorithm.
  • Keywords
    Gaussian distribution; electrocardiography; filtering theory; medical signal detection; medical signal processing; obstetrics; patient monitoring; time series; Gaussian distribution; Physionet Scoring System; abdominal recordings; expectation-weighted estimation; fQRS time series; fiducial points; foetal distress; grid search; high-pass filtered abdominal ECG; low-pass filtering; maternal ECG; maternal QRS; morbidity; multichannel foetal heartbeat detection; noninvasive fHR monitoring; notch-filtered abdominal ECG; source cancellation; Abstracts; Acceleration; Estimation; Glass; Real-time systems; Scalp; Silicon;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computing in Cardiology Conference (CinC), 2013
  • Conference_Location
    Zaragoza
  • ISSN
    2325-8861
  • Print_ISBN
    978-1-4799-0884-4
  • Type

    conf

  • Filename
    6712478