Salt fog testing of glass insulators with different surface conditions
Author :
Meyer, L.H. ; Werner Beyer, Wagner ; Hidalgo Molina, Fernando
Author_Institution :
Dept. of Electr. & Telecommun. Eng., Univ. of Blumenau, Blumenau, Brazil
fYear :
2013
fDate :
2-4 Oct. 2013
Firstpage :
1
Lastpage :
4
Abstract :
This work explores the salt fog test to evaluate the performance of glass insulators used in a 230 kV transmission line. Three types of glass insulators were used, from the field with original contamination, a clean one, and a RTV coated one. The results have demonstrated that the pre-contamination have a role in salt fog performance and that the RTV coated insulator has shown least leakage current and was the last to fail in the salt fog.
Keywords :
fog; glass; insulators; materials testing; power transmission lines; RTV coated insulator; contamination; glass insulators performance; leakage current; salt fog performance; salt fog testing; surface conditions; transmission line; voltage 230 kV; Contamination; Glass; Insulators; RTV coating; contamination performance; glass insulator; leakage current; salt fog;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Power and Energy Conversion Systems (EPECS), 2013 3rd International Conference on
Conference_Location :
Istanbul
Print_ISBN :
978-1-4799-0687-1
Type :
conf
DOI :
10.1109/EPECS.2013.6713083