DocumentCode
674507
Title
Noncontact sensing of electrocardiographic potential and body proximity by in-bed conductive fabrics
Author
Ito, Kei ; Fukuoka, Yoshitaka ; Cauwenberghs, Gert ; Ueno, Atsushi
Author_Institution
Tokyo Denki Univ., Tokyo, Japan
fYear
2013
fDate
22-25 Sept. 2013
Firstpage
523
Lastpage
526
Abstract
Aging populations call for pervasive monitoring of activity of elderly patients and their electrocardiographic potential (ECG) in the hospital or at home. In this study, we propose a noncontact approach for continuous sensing of presence, position and ECG of a human body on a bed. Six pieces of belt-like conductive fabrics were used as sensing electrodes. Three of the pieces were connected to a newly developed ECG amplifier featuring ultra-high input impedance. The other three pieces were connected to two sets of capacitance meters. Capacitances for upper and lower bodies were separately measured. A male volunteer subject was instructed to sit down on a bed, lie on the bed in a supine position, and change to a lateral position atfixed time intervals. In result, the combination of two voltages, inversely proportional to the upper and lower body coupling capacitances, varied in accordance with the change in the subject´s position. In addition ECG was detected in the periods when the subject was in supine or lateral position. And distinct QRS complexes and T-waves were confirmed, though some distortion can be observed. These results demonstrate the potential of the proposed approach for Aging populations call for pervasive monitoring of activity of elderly patients and their electrocardiographic potential (ECG) in the hospital or at home. In this study, we propose a noncontact approach for continuous sensing of presence, position and ECG of a human body on a bed. Six pieces of belt-like conductive fabrics were used as sensing electrodes. Three of the pieces were connected to a newly developed ECG amplifier featuring ultra-high input impedance. The other three pieces were connected to two sets of capacitance meters. Capacitances for upper and lower bodies were separately measured. A male volunteer subject was instructed to sit down on a bed, lie on the bed in a supine position, and change to a lateral position at fixed time intervals. In result, the combination of two- voltages, inversely proportional to the upper and lower body coupling capacitances, varied in accordance with the change in the subject´s position. In addition ECG was detected in the periods when the subject was in supine or lateral position. And distinct QRS complexes and T-waves were confirmed, though some distortion can be observed. These results demonstrate the potential of the proposed approach for noncontact sensing of ECG and lying body capacitance toward awareness-free pervasive and continuous monitoring.noncontact sensing of ECG and lying body capacitance toward awareness-free pervasive and continuous monitoring.
Keywords
amplifiers; bioelectric potentials; biomedical equipment; capacitance measurement; conducting materials; electrocardiography; fabrics; geriatrics; patient monitoring; ECG amplifier input impedance; ECG detection; QRS complexes; T-waves; awareness-free continuous monitoring; awareness-free pervasive monitoring; belt-like conductive fabrics; capacitance meters; continuous ECG sensing; continuous human body position sensing; continuous human body presence sensing; elderly patients ECG monitoring; elderly patients activity monitoring; home monitoring; hospital monitoring; in-bed conductive fabrics; lateral lying position; lower bodies capacitances measurement; lower body coupling capacitances; noncontact body proximity sensing; noncontact electrocardiographic potential sensing; noncontact lying body capacitance sensing; sensing electrodes; sitting position; supine lying position; upper bodies capacitances measurement; upper body coupling capacitances; Abstracts; Electric potential; Electrocardiography; Electrodes; Insulators; Monitoring; Power filters;
fLanguage
English
Publisher
ieee
Conference_Titel
Computing in Cardiology Conference (CinC), 2013
Conference_Location
Zaragoza
ISSN
2325-8861
Print_ISBN
978-1-4799-0884-4
Type
conf
Filename
6713429
Link To Document