DocumentCode :
674650
Title :
The effect of the sensor position of the pressure wire distal to a coronary stenosis on the calculated fractional flow reserve
Author :
Tar, Bora ; Bakk, S. ; Beres, Z. ; Santa, Jose ; Polgar, P. ; Shengxian Tu ; Koszegi, Zsolt
Author_Institution :
Invasive Cardiology Lab., Josa Andras Teaching Hosp., Nyiregyhaza, Hungary
fYear :
2013
fDate :
22-25 Sept. 2013
Firstpage :
1099
Lastpage :
1102
Abstract :
The determination of the fractional flow reserve can be influenced by the position of the sensor of the pressure wire distal to a coronary lesion. We aimed to calculate the pressure gradients restricted to the stenosis and with the inclusion of the distal reference segment up to the position of the pressure wire. The coronary artery volumetric flow was calculated based on the velocity of the contrast material in the 3D reconstructed coronary segment. Pressure gradients were determined by fluid dynamic equations using the morphological data derived from 3D coronary angiography and contrast material velocities. The Bland-Altman analysis showed smaller diferences between the calculated and the measured FFR when the distal laminar resistances were also incorporated in the model, compared to the calculations restricted to the lesions (mean difference: -0.05 vs. -0.09, limits: -0.11-0.02 vs. -0.16-0.01; range: 0.112 vs. 0.159). The FFR reflects not only the pressure gradient of the stenosis, but also the laminar resistance of the poststenotic segment. Knowing the components of the detected gradients could be important for the clinical considerations of the cases near the cut-off value of the FFR.
Keywords :
angiocardiography; blood flow measurement; blood vessels; diagnostic radiography; diseases; electrocardiography; image reconstruction; laminar flow; medical image processing; pressure sensors; statistical analysis; 3D coronary segment reconstruction; Bland-Altman analysis; contrast material velocities; coronary angiography; coronary artery volumetric flow calculation; coronary lesion; coronary stenosis; distal laminar resistances; fluid dynamic equations; fractional flow reserve calculation; fractional flow reserve measurement; morphological data; poststenotic segment; pressure gradient calculation; pressure sensor guide wire; Abstracts; Biomedical imaging; Computed tomography; Image reconstruction; Materials; Predictive models; Wires;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computing in Cardiology Conference (CinC), 2013
Conference_Location :
Zaragoza
ISSN :
2325-8861
Print_ISBN :
978-1-4799-0884-4
Type :
conf
Filename :
6713573
Link To Document :
بازگشت