• DocumentCode
    682312
  • Title

    Complex method of comprehensively evaluation and fault diagnosis in gun control system based on fuzzy reasoning

  • Author

    Zhang Lei ; Chang Tianqing ; Zhang Yang ; Su Jian

  • Author_Institution
    Dept. of Control Eng., Acad. of Armored Force Eng., Beijing, China
  • Volume
    2
  • fYear
    2013
  • fDate
    16-19 Aug. 2013
  • Firstpage
    855
  • Lastpage
    858
  • Abstract
    Aiming at the character and difficulty of comprehensively evaluation and fault diagnosis in gun control system, based on fuzzy analytic hierarchy process(F-AHP), the evaluating indicator architecture is established. Membership functions of voltage signal, current signal, flux signal, and I/O signal are proposed, and the weight of each quality is calculated. Based on the difference weight and fuzzy mathematic theory, the process of fault diagnosis is optimized, at the same time the performance is evaluated. Finally, the system is applied successfully in practice.
  • Keywords
    analytic hierarchy process; electric current control; fault diagnosis; fuzzy reasoning; fuzzy set theory; voltage control; weapons; F-AHP; comprehensive evaluation; current signal; difference weight; evaluating indicator architecture; fault diagnosis; flux signal; fuzzy analytic hierarchy process; fuzzy mathematic theory; fuzzy reasoning; gun control system; input-output signal; membership functions; quality weight; voltage signal; Cognition; Control systems; Fault diagnosis; Fuzzy reasoning; Indexes; Vectors; evaluation; fault diagnosis; fuzzy rules; gun control system;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Measurement & Instruments (ICEMI), 2013 IEEE 11th International Conference on
  • Conference_Location
    Harbin
  • Print_ISBN
    978-1-4799-0757-1
  • Type

    conf

  • DOI
    10.1109/ICEMI.2013.6743210
  • Filename
    6743210