DocumentCode
682746
Title
Video-based heart rate measurement using head motion tracking and ICA
Author
Li Shan ; Minghui Yu
Author_Institution
Sch. of Autom., Huazhong Univ. of Sci. & Technol., Wuhan, China
Volume
01
fYear
2013
fDate
16-18 Dec. 2013
Firstpage
160
Lastpage
164
Abstract
A noninvasive and easy-operation measurement of the heart rate has great potential in home healthcare. We present a simple and high running efficiency method for measuring heart rate from a video. By only tracking one feature point which is selected from a small ROI (Region of Interest) in the head area, we extract trajectories of this point in both X-axis and Y-axis. After a series of processes including signal filtering, interpolation, the Independent Component Analysis (ICA) is used to obtain a periodic signal, and then the heart rate can be calculated. We evaluated on 10 subjects and compared to a commercial heart rate measuring instrument (YUYUE YE680B) and achieved high degree of agreement. A running time comparison experiment to the previous proposed motion-based method is carried out and the result shows that the time cost is greatly reduced in our method.
Keywords
image motion analysis; independent component analysis; medical computing; video signal processing; ICA; ROI; feature point tracking; head motion tracking; heart rate measuring instrument; independent component analysis; interpolation; region of interest; signal filtering; video-based heart rate measurement; Biomedical monitoring; Feature extraction; Finite impulse response filters; Heart rate measurement; IIR filters; Tracking; Independent Component Analysis (ICA); heart rate measurement; motion tracking; noninvasive;
fLanguage
English
Publisher
ieee
Conference_Titel
Image and Signal Processing (CISP), 2013 6th International Congress on
Conference_Location
Hangzhou
Print_ISBN
978-1-4799-2763-0
Type
conf
DOI
10.1109/CISP.2013.6743978
Filename
6743978
Link To Document