• DocumentCode
    684131
  • Title

    Establishing correction factors for the partitioning of furanic derivatives between oil and paper insulation

  • Author

    Lessard, Marie-Claude ; Jalbert, J. ; Ryadi, Mohamed

  • Author_Institution
    Hydro-Quebec (IREQ), Varennes, QC, Canada
  • fYear
    2013
  • fDate
    20-23 Oct. 2013
  • Firstpage
    132
  • Lastpage
    135
  • Abstract
    This paper deals with the effect of the temperature on the partition of the furanic derivatives between the oil and paper insulation in power transformers. For the five chemical markers studied, due to its highest polarity, the 2-furfurol showed the highest difference compared to the other furanic species. The author´s propose correction equations at 20°C for the normalization of the temperature for the furanic derivatives. These correction factors allow following the real trend of the markers during all the transformer life.
  • Keywords
    power transformer insulation; transformer oil; correction factors; furanic derivatives; oil insulation; paper insulation; power transformers; temperature 20 degC; Aging; Chemicals; Mathematical model; Oil insulation; Power transformer insulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena (CEIDP), 2013 IEEE Conference on
  • Conference_Location
    Shenzhen
  • Type

    conf

  • DOI
    10.1109/CEIDP.2013.6748198
  • Filename
    6748198