Abstract
Impact of channel model parameters on the whole-body specific absorption rate (SAR) is studied. Closed-form expressions are derived for the mean value and the standard deviation of the SAR, taking into account the random nature of the channel parameters. Total sensitivity indices of the SAR with respect to the channel parameters are derived. They are estimated using a Monte-Carlo approach. Noninfluential channel parameters are identified. They are then suppressed from channel models for dosimetry purpose.
Keywords
MIMO communication; Monte Carlo methods; dosimetry; electromagnetic wave absorption; wireless channels; Monte-Carlo approach; SAR; channel model parameters; channel models; noninfluential channel parameters; sensitivity indices; standard deviation; whole-body dosimetry; whole-body specific absorption rate; Channel models; Convergence; Dosimetry; Finite difference methods; Monte Carlo methods; Sensitivity analysis; Child body model; Dosimetry; Sensitivity Analysis; Wireless Channel; dosimetry; sensitivity analysis; wireless channel;