Scatter and attenuation corrections for a PEM detector using List-Mode OSEM
Author :
Ferreira, Cleber S. ; Cao, L. ; Bugalho, Ricardo ; Matela, Nuno ; Ortigao, Catarina ; Varela, Jesus ; Almeida, Paulo
Author_Institution :
Inst. de Biofisica e Eng. Biomed., Univ. de Lisboa, Lisbon, Portugal
fYear :
2013
fDate :
Oct. 27 2013-Nov. 2 2013
Firstpage :
1
Lastpage :
4
Abstract :
Emission Tomography imaging techniques are known for its quantitative potential. As in whole-body Positron Emission Tomography (PET), also in breast dedicated Positron Emission Mammography (PEM) systems, this goal can only be achieved if a set of corrections for known physics processes is implemented thoroughly. Corrections for Compton scattered events, photon attenuation and random events are examples of such important data corrections. In this work, we report the performance of scatter and attenuation corrections, specifically implemented for PEM. These correction methods were tested on data from the ClearPEM scanner, a dual-head planar system. The ClearPEM scanner does not incorporate transmission images for attenuation correction. With no anatomical information available, the PEM emission image was used to obtain the acquisition´s characteristics needed as input for both the Monte Carlo (MC) based scatter correction method and the attenuation correction algorithm. A MC scatter correction can accurately model the scatter distribution of a PEM acquisition, but removing this estimate from the acquired data can result in a severe bias and increased noise in low counts PEM studies. To avoid such drawbacks, an approach based on a smoothed imaged of the scatter distribution was used. Due to the typically low counts nature of PEM acquisitions, correction procedures were combined with a 3D-OSEM-LM reconstruction, so reconstructed images could be obtained in a short period of time. Results demonstrated that both corrections perform as expected. The presence of scattered events was strongly reduced. Counts loss due to photon attenuation was clearly compensated, along with the recovery of the correct activity distribution.
Keywords :
Compton effect; Monte Carlo methods; expectation-maximisation algorithm; mammography; medical image processing; positron emission tomography; ClearPEM scanner; Compton scattered events; Monte Carlo method; PEM detector; activity distribution; attenuation corrections; breast dedicated positron emission mammography; dual-head planar system; list-mode OSEM; photon attenuation; random events; scatter corrections; whole-body positron emission tomography; Attenuation; Breast; Detectors; Image reconstruction; Monte Carlo methods; Phantoms; Photonics;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Conference_Location :
Seoul
Print_ISBN :
978-1-4799-0533-1
Type :
conf
DOI :
10.1109/NSSMIC.2013.6829264
Filename :
6829264
Link To Document :
بازگشت