Title : 
Monte Carlo simulations on GPU for brachytherapy applications
         
        
            Author : 
Lemarechal, Yannick ; Bert, Julien ; Boussion, Nicolas ; Le Fur, Emmanuelle ; Visvikis, D.
         
        
            Author_Institution : 
LaTIM, CHRU Brest, Brest, France
         
        
        
            fDate : 
Oct. 27 2013-Nov. 2 2013
         
        
        
        
            Abstract : 
In brachytherapy, dosimetric plans are routinely calculated with the TG43 formalism which considers the patient as a simple water box. However, accurate modelling of the physical processes considering patient heterogeneity using Monte Carlo (MC) methods is currently too time-consuming and computationally demanding to be routinely used. As a solution we implemented an accurate and fast MC simulation based on Geant4 on graphics processing units (GPU) for brachytherapy applications. Existing approaches using GPU architecture for brachytherapy MC simulations suffer from numerous approximations including, the use of virtual seed bound to a phase space file to define dwell sources, or removing voxel within the CT image to include seed density. Within the proposed framework such approximations have been removed. A comparison between dosimetric plans based on the current clinical standard (TG43) and the proposed full MC simulation led to substantial differences due to the TG43 related approximations assuming the patient as a water box. Finally, the proposed dosimetry platform is capable of providing accurate dose distributions within one minute, which is compatible for a clinical routine usage.
         
        
            Keywords : 
Monte Carlo methods; brachytherapy; computerised tomography; dosimetry; graphics processing units; CT image; GPU architecture; Monte Carlo simulations; TG43 formalism; brachytherapy applications; dose distribution accuracy; dosimetric plans; graphics processing units; patient heterogeneity; phase space file; time 1 min; virtual seed bound; voxel removal; Brachytherapy; Dosimetry; Energy resolution; Graphics processing units; Navigation; Phantoms; Ultrasonic imaging;
         
        
        
        
            Conference_Titel : 
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
         
        
            Conference_Location : 
Seoul
         
        
            Print_ISBN : 
978-1-4799-0533-1
         
        
        
            DOI : 
10.1109/NSSMIC.2013.6829314