Title :
Multi-centre assessment of HRRT image uniformity via 68Ge and 18F cylindrical and anthropomorphic phantoms
Author :
Reader, Andrew J. ; Tahaei, Marzieh S. ; Rahmim, Arman ; Keller, Sune H. ; Blinder, Stephan ; Sibomana, Merence ; Soucy, Jean-Paul
Author_Institution :
Montreal Neurological Inst., McGill Univ., Montreal, QC, Canada
fDate :
Oct. 27 2013-Nov. 2 2013
Abstract :
To date, the high resolution research tomograph (HRRT) still offers the highest resolution PET imaging capability of the human brain. Spatial uniformity of the images is of paramount importance, as many radioligand studies require either accurate regional dynamic quantification or, at the very least, accurate measurement of relative activities between regions. Often uniform cylinders, of 68Ge or 18F, are used for quality control and calibration purposes. This work examines the spatial uniformity obtained in reconstructed images of uniform cylinders from seven different HRRT centres, using either 68Ge or 18F, and also considering a head and brain phantom filled with 18F scanned at three of the centres. To account for varying activity levels used in each centre´s data acquisition, and possibly different image reconstruction parameters, a progressive smoothing method was used to analyze image uniformity, with metrics designed to assess non-uniformity in image planes as well as in randomly selected region of interest pairs. Unusually high image non-uniformities were found for germanium cylinders at two centres, but of greater concern was the fact that uniformity for the brain phantom was found to be notably inferior at two of the three centres which scanned the phantom. A change of mumap reconstruction parameters, and minor adjustment of a parameter used in the single scatter simulation, was shown to remedy the issue (reducing relative region errors to <;5%).
Keywords :
brain; calibration; data acquisition; fluorine; germanium; image reconstruction; image resolution; medical image processing; phantoms; positron emission tomography; smoothing methods; 18F anthropomorphic phantoms; 18F cylindrical phantoms; 68Ge anthropomorphic phantoms; 68Ge cylindrical phantoms; HRRT image uniformity; brain phantom; calibration; centre data acquisition; head phantom; high resolution research tomography; highest resolution PET imaging capability; human brain; image planes; image reconstruction parameters; image uniformity; mu-map reconstruction parameters; multicentre assessment; progressive smoothing method; quality control; radioligand; randomly selected region-of-interest pairs; regional dynamic quantification; relative region errors; single scatter simulation; spatial uniformity; unusually high-image nonuniformities; Brain modeling; Germanium; Image reconstruction; Phantoms; Smoothing methods; Standards; Three-dimensional displays;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Conference_Location :
Seoul
Print_ISBN :
978-1-4799-0533-1
DOI :
10.1109/NSSMIC.2013.6829403