  • Abstract
    Ion Back Flow (IBF) suppression is essential to avoid a space-charge distortion of the electric field under a high rate condition for the Time Projection Chamber (TPC). We developed Thick COBRA GEMs to investigate a capability of IBF suppression. It was found that the COBRA GEM can suppress IBF more effectively compared to a standard GEM. IBF reaches about 0.1-0.5% and energy resolution (σ) is ~ 20% with a stack configuration consisting of one standard GEM facing to the drift field and two COBRA GEMs.
  • Keywords
    ionisation chambers; time projection chambers; COBRA GEM; GEM-based TPC application; IBF suppression; Time Projection Chamber; drift field; electric field; high rate condition; ion back flow; space-charge distortion; Absorption; Electrodes; Electron tubes; Energy resolution; Ions; Pulse measurements; Standards;