    Neutron damage in mechanically-cooled high-purity germanium detectors for field-portable Prompt Gamma Neutron Activation analysis (PGNAA) systems

  • Author

    Seabury, E.H. ; Van Siclen, C. Dew ; McCabe, J.B. ; Wharton, C.J. ; Caffrey, A.J.

  • Author_Institution
    Idaho Nat. Lab., Idaho Falls, ID, USA
  • fYear
    2013
  • fDate
    Oct. 27 2013-Nov. 2 2013
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Prompt Gamma Neutron Activation (PGNAA) systems require the use of a gamma-ray spectrometer to record the gamma-ray spectrum of an object under test and allow the determination of the object´s composition. Field-portable systems, such as Idaho National Laboratory´s PINS system, have used standard liquid-nitrogen-cooled high-purity germanium (HPGe) detectors to perform this function. These detectors have performed very well in the past, but the requirement of liquid-nitrogen cooling limits their use to areas where liquid nitrogen is readily available or produced on-site. Also, having a relatively large volume of liquid nitrogen close to the detector can impact some assessments, possibly leading to a false detection of explosives or other nitrogen-containing chemical. Use of a mechanically-cooled HPGe detector is therefore very attractive for PGNAA applications where nitrogen detection is critical or where liquid-nitrogen logistics are problematic. Mechanically-cooled HPGe detectors constructed from p-type germanium, such as ORTEC´s TransSpec, have been commercially available for several years. In order to assess whether these detectors would be suitable for use in a fielded PGNAA system, Idaho National Laboratory (INL) has been performing a number of tests of the resistance of mechanically-cooled HPGe detectors to neutron damage. These detectors have been standard commercially-available p-type HPGe detectors as well as prototype n-type HPGe detectors. These tests compare the performance of these different detector types as a function of crystal temperature and incident neutron fluence on the crystal.
  • Keywords
    explosive detection; gamma-ray detection; gamma-ray spectrometers; germanium radiation detectors; neutron activation analysis; Idaho National Laboratory; crystal temperature; explosives detection; field portable PGNAA system; gamma-ray spectrometer; gamma-ray spectrum recording; liquid nitrogen cooled HPGe detector; liquid nitrogen cooling limits; mechanically cooled high purity germanium detector; neutron damage; object composition determination; p-type HPGe detector; prompt gamma neutron activation analysis; prototype n-type HPGe detector; Crystals; Detectors; Gamma-rays; Germanium; Neutrons; Pins; Radiation effects;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
  • Conference_Location
    Seoul
  • Print_ISBN
    978-1-4799-0533-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2013.6829527
  • Filename
    6829527