• DocumentCode
    687107
  • Title

    The NA62 RICH detector

  • Author

    Anzivino, G. ; Bucci, F. ; Carassiti, V. ; Cassese, A. ; Cenci, P. ; Ciaranfi, R. ; Duk, V. ; Iacopini, E. ; Lami, S. ; Lenti, M. ; Pepe, Monica ; Piandani, R. ; Piccini, M. ; Sergi, A.

  • Author_Institution
    Phys. Dept., Perugia Univ., Perugia, Italy
  • fYear
    2013
  • fDate
    Oct. 27 2013-Nov. 2 2013
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    The main goal of the NA62 experiment is the measurement of the K+ → π+νν̅ branching ratio with a precision better than 10%. One of the key element of NA62 is the Ring Imaging CHerenkov detector (RICH). It will identify pions and muons in the momentum range between 15 and 35 GeV/c, with a muon rejection factor better than 10-2. The RICH will also measure the particle arrival time with a precision better than 100 ps to disentangle accidental time associations of beam particles with pions and will provide the reference time and a fast signal for the NA62 trigger system. We present the final design of the detector and the status of the construction. Finally, we recall the results of the beam tests of the RICH prototype.
  • Keywords
    Cherenkov counters; muon detection; NA62 RICH detector; NA62 experiment; NA62 trigger system; RICH prototype; Ring Imaging CHerenkov detector; accidental time associations; beam particles; beam tests; branching ratio; kaon+ decay into pion++neutrino+antineutrino; muon rejection factor; particle arrival time; reference time; Atmospheric measurements; Detectors; Mesons; Mirrors; Physics; Structural beams; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
  • Conference_Location
    Seoul
  • Print_ISBN
    978-1-4799-0533-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2013.6829549
  • Filename
    6829549