Title : 
Comparative study of scintillation properties of BaF2 and BaMgF4 scintillators using streak camera system equipped with pulsed X-ray source
         
        
            Author : 
Fujimoto, Yasutaka ; Yanagida, T. ; Kawaguchi, Noriyuki ; Fukuda, Kenji
         
        
            Author_Institution : 
Kyushu Inst. of Technol., Kitakyushu, Japan
         
        
        
            fDate : 
Oct. 27 2013-Nov. 2 2013
         
        
        
        
            Abstract : 
By using the micro-pulling down (μ-PD) method, the barium magnesium fluoride (BaMgF4) single crystalline scintillator was produced. The crystal was cut and mirror polished to the physical dimensions of 1× 2× 10 mm3 for examination of optical and scintillation properties. BaMgF4 exhibited more than 70 % transmittance in wavelength range from 170 to 2500 nm, and strong emission peaking around 205 nm was observed under X-ray excitation. The absolute light yield of BaMgF4 was 1300±100 ph/MeV, and the decay time profile showed two components as 0.45 (76 %) and 1.4 (24 %) ns at room temperature.
         
        
            Keywords : 
barium compounds; particle detectors; solid scintillation detectors; BaF2; BaMgF4; X-ray excitation; decay time profile; micropulling down method; optical properties; pulsed X-ray source; scintillation properties; single crystalline scintillator; streak camera system; temperature 293 K to 298 K; wavelength 170 nm to 2500 nm; Biomedical optical imaging; Cameras; Crystals; Electron tubes; Optical imaging; Optical sensors; Temperature measurement;
         
        
        
        
            Conference_Titel : 
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
         
        
            Conference_Location : 
Seoul
         
        
            Print_ISBN : 
978-1-4799-0533-1
         
        
        
            DOI : 