DocumentCode
687299
Title
The status of high-speed trigger multiplexer module with aurora protocol implemented on Arria II FPGA for the Belle II Cylindrical Drift Chamber detector
Author
Teng, Y.-S. ; Wang, Ching-Hung ; Liu, S.-M. ; Shiu, J.-G. ; Lai, Yi-Tse ; Lin, C.-S.
Author_Institution
Electr. Eng. Dept., Nat. United Univ., Miaoli, Taiwan
fYear
2013
fDate
Oct. 27 2013-Nov. 2 2013
Firstpage
1
Lastpage
3
Abstract
Based on the first prototype, a newly modified trigger multiplexer module (merger) is under development for the Central Drift Chamber (CDC) detector which will be used in the future Belle II experiment. The features of modified merger circuit board include two Arria II FPGAs, four 3.125G optical modules and one 6.25G optical module for data transmission. The modified circuit board of merger was made and the data-link testing with Aurora protocol between the merger and the main trigger system (UT3) has been performed. Simple data reduction scheme within mergers and the schedule of the production plan will also be included here.
Keywords
data reduction; drift chambers; field programmable gate arrays; optical modulation; protocols; Arria II FPGA; Belle II cylindrical drift chamber detector; CDC detector; aurora protocol; data reduction scheme; data transmission; data-link testing; high-speed trigger multiplexer module; main trigger system; modified merger circuit; modified trigger multiplexer module; optical module; Corporate acquisitions; Data communication; Detectors; Field programmable gate arrays; Optical fibers; Printed circuits; Protocols;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Conference_Location
Seoul
Print_ISBN
978-1-4799-0533-1
Type
conf
DOI
10.1109/NSSMIC.2013.6829748
Filename
6829748
Link To Document