Abstract :
As a result of world´s energy resources crisis and environment pollution increasingly aggravating, distributed generation (DG) based on renewable energy has become a developmental trend for electric power industry in 21 century. However, DG´s are usually affected by natural conditions being not able to output power continuously and steadily, so when large scale wind turbine generators are incorporated into the grid there is likely attendance impact it would bring on electric power system stability. In this investigation, the wind farm connection was done at 33/1 1kV level at Kastina substation located at Northern part of Nigeria. This paper is to establish voltage instability and frequency fluctuation that might be associated with the connection of the wind farm to the existing grid. The DigSILENT Power Factory software was used for modeling and simulation analysis of the studies and the results shows that when wind farm is connected to the grid, large clearance time is required for the fault to be cleared for voltage and frequency to become normalize again as compare with normal grid system. The studies has verified transient stability associated problem due to voltage and frequency stability variation phenomenon during the disconection of both windfarm and the load from the existing grid and is easier to predict in future the setting of protective devices and clearance time.
Keywords :
distributed power generation; fault diagnosis; power grids; power system transient stability; wind power plants; wind turbines; 3-Φ short circuit; DG; DigSILENT Power Factory software; Kastina substation; PCC; clearance time; contingency condition; continuous operation; distributed generation; electric power industry; electric power system stability; energy resources crisis; environment pollution; frequency fluctuation; frequency stability variation phenomenon; grid connected Kastina wind farm; large scale wind turbine generators; normal grid system; power 10 MW; protective devices; transient stability; voltage 11 kV; voltage 33 kV; voltage instability; voltage stability variation phenomenon; Circuit stability; Power system stability; Rotors; Stability analysis; Transient analysis; Wind farms; Continuous Operation; Grid code; PCC; Transient Stability; Wind Farm;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power and Energy Engineering Conference (APPEEC), 2013 IEEE PES Asia-Pacific
Conference_Location :
Kowloon
Type :
conf
DOI :
10.1109/APPEEC.2013.6837109
Filename :
6837109
Link To Document :
بازگشت