Abstract :
Experimental studies are reported that measuring results of electric field mill are inconsistency, which affects their measuring accuracy. This paper introduces the principle of electric field measurement. Statistical analysis of calibration experimental results shows that measurement data obey normal distribution rule. Correlation analysis result indicates that the distance between two electrodes of field mill has a strong linear correlation with measure results. Linear model is established with the method of regression analysis. Finally, residual test verify the rationality of regression model.
Keywords :
calibration; correlation theory; data integrity; electric field measurement; regression analysis; calibration; correlation analysis; data consistency; electric field measurement; field mill electrodes; linear correlation; linear model; normal distribution rule; regression analysis; regression model; residual test; statistical analysis; Correlation; Electric fields; Electrodes; Fitting; Gaussian distribution; Transmission line measurements; Electric field mill; consistency; correlation; regression analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation, Measurement, Computer, Communication and Control (IMCCC), 2013 Third International Conference on
Conference_Location :
Shenyang
Type :
conf
DOI :
10.1109/IMCCC.2013.14
Filename :
6840403
Link To Document :
بازگشت