• DocumentCode
    696267
  • Title

    FDI using high gain observers for cascade systems: Application to induction motors

  • Author

    Mahamoud, Ayan ; Glumineau, Alain ; Souleiman, Ibrahim

  • Author_Institution
    Univ. de Djibouti, Djibouti, Djibouti
  • fYear
    2009
  • fDate
    23-26 Aug. 2009
  • Firstpage
    3106
  • Lastpage
    3111
  • Abstract
    This paper proposes a FDI strategy using high gain observers. Observers are often necessary for control purpose. It is possible to extend their application to disturbance estimation and FDI strategy. The observer is designed for a performance study on an induction motor in the framework of a specific induction motor Fault Diagnosis Benchmark.
  • Keywords
    fault diagnosis; induction motors; observers; FDI strategy; high gain observers; induction motor fault diagnosis benchmark; industrial systems; Induction motors; Mathematical model; Observers; Stator windings; Torque; Vectors;
  • fLanguage
    English
  • Publisher