Title : 
Operation evaluations in high speed range of wound field synchronous motor drive integrated with ZSI
         
        
            Author : 
Tajima, G. ; Kosaka, T. ; Matsui, N. ; Tonogi, K. ; Minoshima, N. ; Yoshida, T.
         
        
            Author_Institution : 
Dept. of Comput. Sci. & Eng., Nagoya Inst. of Technol., Nagoya, Japan
         
        
        
        
        
        
            Abstract : 
This paper presents experimental evaluations of drive performances in high-speed range of a wound field synchronous motor (WFSM) drive system integrated with a z-source inverter (ZSI). The WFSM has two field coils as DC field mmf sources instead of permanent magnets. On the other hand, the ZSI employs an impedance-network that consists of two DC reactors and two capacitors. A uniqueness of the proposed drive system lies in that this system makes it possible to reduce size and cost because the two DC reactors serve as both two field coils as the DC field mmf sources in the WFSM and the DC boosting reactors in the ZSI. The comparisons of drive performances in high-speed range between the proposed integrated system and a non-integrated system are experimentally demonstrated and discussed.
         
        
            Keywords : 
coils; invertors; machine windings; synchronous motor drives; DC boosting reactor; WFSM drive system; ZSI; capacitor; impedance-network; integrated system; nonintegrated system; permanent magnet; wound field synchronous motor drive system; z-source inverter; Capacitors; Coils; Inverters; Synchronous motors; Torque; Voltage control; Windings; boost-up/field current control; integrated motor and drive circuit system; wound field synchronous motor; z-source inverter;
         
        
        
        
            Conference_Titel : 
Mechatronics (ICM), 2015 IEEE International Conference on
         
        
            Conference_Location : 
Nagoya
         
        
        
            DOI : 
10.1109/ICMECH.2015.7084060