DocumentCode
704286
Title
New approach for 6 cylinder diesel electric algorithm control on one cylinder failure
Author
Shifte, Changiz ; Abedini, Hossein ; Akbarifard, Abdolmajid ; Ebrahim Afjei, S.
Author_Institution
Marine Propulsion Inst., Marine Ind. Organ., Tehran, Iran
fYear
2015
fDate
3-4 Feb. 2015
Firstpage
103
Lastpage
106
Abstract
Because of nonresistance loading, stability of local network electricity frequency is very important in the alternative electricity generator. Since load consumer equipment would be damaged if the frequency is not in the allowable range, so the frequency fluctuation must be as low as it is possible. Non fluctuated frequency of diesel-electric alternator dependents on the diesel engine speed stability, so keeping the speed in stability range is very important. There is a 6 cylinder diesel-electric that work in part load and a failure takes place suddenly in one of the cylinders. So a new approach control algorithm is presented for keeping engine speed in the allowable range.
Keywords
controllers; diesel engines; diesel-electric generators; three-term control; 6 cylinder diesel electric algorithm control; diesel engine speed stability; diesel-electric alternator; frequency fluctuation; local network electricity frequency; one cylinder failure; Engines; Frequency control; Generators; Presses; Control; Diesel-Electric; Failure; PID;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics, Drives Systems & Technologies Conference (PEDSTC), 2015 6th
Conference_Location
Tehran
Print_ISBN
978-1-4799-7652-2
Type
conf
DOI
10.1109/PEDSTC.2015.7093257
Filename
7093257
Link To Document