DocumentCode :
704581
Title :
Turn to turn fault detection and classification in stator winding of synchronous generators based on terminal voltage waveform components
Author :
Fayazi, Mohammad ; Haghjoo, Farhad
Author_Institution :
Electr. Eng. Dept., Shahid Beheshti Univ., Tehran, Iran
fYear :
2015
fDate :
14-15 Jan. 2015
Firstpage :
36
Lastpage :
41
Abstract :
In this paper, a novel method is presented to detect and classify turn-turn faults (TTF) in stator winding of the synchronous generators on the basis of resulting harmonics contents in the terminal voltage waveforms. Analytical results by using Decision Tree (DT) show that this algorithm is practicable using only the first harmonic of residual voltage and only two harmonic component values. Simulations in Maxwell software are done using Fuji´s technical documents and data sheets of an actual salient pole synchronous generator (one unit of an Iran´s hydroelectric power plants) and all of related parameters (such as B-H curve, unsymmetrical air gap and pole saliency, slot-teeth effect, and so on) are considered to obtain a comprehensive model, without any simplifier assumption.
Keywords :
decision trees; fault diagnosis; machine protection; stators; synchronous generators; Maxwell software; decision tree; salient pole synchronous generator; stator winding; terminal voltage waveform components; terminal voltage waveform harmonic contents; turn-to-turn fault detection; turn-turn fault classification; Atmospheric modeling; Circuit faults; Harmonic analysis; Software; Software algorithms; Stator windings; Synchronous generators; Classification; Decision Tree; Detection; Harmonic Components; Synchronous Generator; Turn-Turn Fault;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Systems Protection and Control Conference (PSPC), 2015 9th
Conference_Location :
Tehran
Type :
conf
DOI :
10.1109/PSPC.2015.7094926
Filename :
7094926
Link To Document :
بازگشت