Title :
Fault diagnosis of the 3 tank system using fuzzy multiple inference modelling
Author :
Lopez-Toribio, C.J. ; Patton, R.J. ; Batt, C. ; Chen, J.
Author_Institution :
Dept. of Electron. Eng., Univ. of Hull, Kingston upon Hull, UK
fDate :
Aug. 31 1999-Sept. 3 1999
Abstract :
This paper proposes a new approach for detecting and isolating faults in a non-linear dynamic process using the multiple model approach. The necessary conditions for the assignability of eigenvalues to a region in the s-plane and the necessary conditions to guarantee the stability of fuzzy models for Takagi-Sugeno (T-S) fuzzy observers are derived. The paper is structured in two stages. The first is to generate residual signals based on a comparison between the actual and estimated states and in the second stage the Takagi-Sugeno fuzzy observer is reconfigured to identify not only the faults but also the degree or severity of each fault. The techniques developed are demonstrated using a laboratory three tank system.
Keywords :
eigenvalues and eigenfunctions; fault diagnosis; fuzzy set theory; linear matrix inequalities; nonlinear dynamical systems; observers; Takagi-Sugeno fuzzy observers; fault diagnosis; fuzzy multiple infinferenceerence modelling; laboratory three tank system; linear matrix inequalities; multiple model approach; nonlinear dynamic process; Eigenvalues and eigenfunctions; Fault diagnosis; Mathematical model; Modeling; Observers; Robustness; Stability analysis; Fault-Tolerant Control; fuzzy logic; linear matrix inequalities; three tank system;
Conference_Titel :
Control Conference (ECC), 1999 European
Conference_Location :
Karlsruhe
Print_ISBN :
978-3-9524173-5-5