Abstract :
The following topics are dealt with: bimodal TWMPI-MRI hybrid scanner - first NMR results; in vivo and ex vivo experimental MPI angiography with high selection field strength and tailored SPIO nanoparticles; analyzing dynamic processes from the raw magnetic particle measurement signal; first 3D dual modality phantom measurement of a hybrid MPI-MRI system using a resistive 12 channel MPI-MRI magnet design; local compression of the magnetic particle imaging system matrix for efficient image reconstruction; investigations on the robustness of particle separation in multicolor magnetic particle imaging; preliminary experimental X-space color MPI; magnetic particle imaging using the viscosity-dependent brownian particle response; reshaping the 2D MPI PSF to be isotropic and sharp using vector acquisition and equalization; high resolution magnetic particle imaging with low density trajectory; imaging and quantification of SPIONs for cancer therapy with magnetic drug targeting; traveling wave MPI goes pre-clinical application; encapsulation of new ferucarbotran nanoparticles into red blood cells as potential MPI contrast agent; in situ and ex vivo MPI performance compared to fluorescent and MRI imaging; SPIO requirements for in vivo sentinel lymph node localization; online coupling of hydrodynamic fractionation with DLS, MALLS and MPS for MPI tracer evaluation; magnetic particle spectroscopy of glioma cells targeted with lactoferrin-conjugated iron oxide nanoparticle contrast agents; effect of immobilisation of magnetic nanoparticles on MPS-signal; Zero Dead Time Rotational Drift Spectroscopy for magnetic particle ensembles; AC-susceptometry of magnetic nanoparticles using an atomic RF magnetometer; characterizing the imaging performance of magnetic tracers by magnetic particle spectroscopy in an offset field; magnetic particle spectroscopy to monitor the behavior of magnetic nanoparticles in different physiological media; SPIO-coating of devices for MPI-guided cardiovasc- lar interventions: proof of principle; changes in the behavior of magnetic iron oxide nanoparticles during cellular uptake detected by magnetic particle spectroscopy; hardware implementation of a 1d MPI hybrid system for targeted drug delivery; tunable in vivo circulation characteristics of PEGylated MPI tracers; effective uniaxial anisotropy in optimized magnetite MPI tracers probed by freezing in a magnetic field;formation of defined SPIO clusters by continuous flow encapsulation; phase-pure iron oxide nanoparticle MPI tracers: comparison of alternative thermal decomposition synthesis strategies; formation of a biocompatible protein corona on magnetic nanoparticles;gram scale synthesis of magnetite nanoparticles optimized for single-core MPI tracers; simultaneous patch reconstruction in magnetic particle imaging; computationally efficient image reconstruction via optimization for X-space MPI; focus field based trajectory elongation in MPI; resolution improvement by decreasing the drive field amplitude; undersampling the system matrix of a single sided MPI-scanner; performance and safety evaluation of a human sized ffl imager concept; preliminary characterization of a laminated iron-core 6.3 t/m ffl magnet; 2d imaging with a single-sided MPI device; simulation study of a novel relaxometer shield design; MPI with a mechanically rotated FFL; a custom low-noise preamplifier for magnetic particle imaging; and sensitivity and dynamic range improvement in MPI by means of a differential detection system.
Keywords :
biomedical MRI; biomedical NMR; cancer; cellular biophysics; image scanners; iron compounds; magnetic particles; molecular biophysics; nanomagnetics; nanomedicine; nanoparticles; physiological models; proteins; tomography; tracers; 12-channel MPI-MRI magnet design; 2D MPI PSF; 3D phantom measurement; DLS-based hydrodynamic fractionation coupling; MALLS-based hydrodynamic fractionation coupling; MPI angiography SPIO nanoparticle; MPI angiography selection field strength; MPI dynamic range improvement; MPI hybrid system hardware implementation; MPI low density trajectory; MPI sensitivity improvement; MPI tracer evaluation; MPI trajectory elongation; MPI-based targeted drug delivery; MPI-guided cardiovascular interventions; MPS-based hydrodynamic fractionation coupling; MPS-signal; MRI imaging; NMR; PEGylated MPI tracer circulation characteristics; SPIO cluster formation; SPIO device coating; SPIO requirement; SPION imaging; SPION quantification; SPION-based cancer therapy; X-space MPI; Zero Dead Time Rotational Drift Spectroscopy; alternating current susceptometry; alternative thermal decomposition synthesis strategies; atomic RF magnetometer; atomic radiofrequency magnetometer; bimodal TWMPI-MRI hybrid scanner; biocompatible protein corona; computationally efficient image reconstruction; continuous flow encapsulation-formed SPIO cluster; custom low-noise preamplifier; differential detection system; drive field amplitude; dual modality phantom measurement; effective uniaxial anisotropy; ex vivo MPI performance; ex vivo experimental MPI angiography; ferucarbotran nanoparticle encapsulation; fluorescent imaging; focus field based trajectory elongation; freezing-probed MPI tracer; glioblastoma cell magnetic particle spectroscopy; high resolution magnetic particle imaging; high-resolution MPI; human sized FFL imager concept performance evalution; human sized FFL imager concept safety evaluation; hybrid MPI-MRI system; in situ MPI performance; in vivo experimental MPI angiography; in vivo sentinel lymph node localization; isotropic MPI PSF; lactoferrin-conjugated iron oxide nanoparticle contrast agent; laminated iron-core 6.3 t/m FFL magnet; magnetic drug targeting; magnetic field freezing; magnetic iron oxide nanoparticle behavioral change; magnetic nanoparticle behavior monitoring; magnetic nanoparticle immobilization; magnetic nanoparticle susceptometry; magnetic particle ensemble; magnetic particle imaging patch reconstruction; magnetic particle imaging preamplifier; magnetic particle imaging system local compression; magnetic particle imaging system matrix; magnetic particle measurement signal; magnetic particle spectroscopy-detected cellular uptake; magnetic resonance imaging; magnetic tracer imaging performance characterization; magnetite nanoparticle gram scale synthesis; magnetite nanoparticle optimization; mechanically rotated FFL; multicolor MPI; multicolor magnetic particle imaging; nanoparticle contrast agent-targeted glioblastoma cell; novel relaxometer shield design simulation study; nuclear magnetic resonance; online hydrodynamic fractionation coupling; optimization-based image reconstruction; optimized magnetite MPI tracer; particle separation robustness; phase-pure iron oxide nanoparticle MPI tracer; physiological media-immersed nanoparticle; polyethylene glycol; potential MPI contrast agent; preliminary experimental X-space color MPI; red blood cell-encapsulated ferucarbotran nanoparticle; resistive MPI-MRI magnet design; sharp MPI PSF; simultaneous patch reconstruction; single sided MPI-scanner; single-core MPI tracers; single-sided MPI device-based 2D imaging; system matrix undersampling; tailored SPIO nanoparticle; three-dimensional phantom measurement; traveling wave MPI preclinical application; tunable in vivo circulation characteristics; vector acquisition; vector equalization; viscosity-dependent brownian particle response;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Magnetic Particle Imaging (IWMPI), 2015 5th International Workshop on
Conference_Location :
Istanbul
Print_ISBN :
978-1-4799-7269-2
Type :
conf
DOI :
10.1109/IWMPI.2015.7106983
Filename :
7106983
Link To Document :
بازگشت