• DocumentCode
    708900
  • Title

    Active feedback real time MPI control software

  • Author

    Padmanaban, Nitish ; Orendorff, Ryan D. ; Konkle, Justin J. ; Goodwill, Patrick W. ; Conolly, Steven M.

  • Author_Institution
    Dept. of Electr. Eng. & Comput. Sci., Univ. of California, Berkeley, Berkeley, CA, USA
  • fYear
    2015
  • fDate
    26-28 March 2015
  • Firstpage
    1
  • Lastpage
    1
  • Abstract
    Real-time MPI [1] has the potential to serve as a noninvasive alternative to X-ray angiography. In order to achieve real time MPI, we must (a.) generate vector-drive field waveforms at a location governed in real time by the physician, (b.) acquire the MPI image data in real time, (c.) reconstruct the MPI images in real time. We have designed our MPI data acquisition and control (DAQ) to enable all these steps in real time.
  • Keywords
    computer software; data acquisition; image reconstruction; magnetic particles; medical image processing; MPI image data; active feedback real time MPI control software; data acquisition; data control; image reconstruction; vector-drive field waveforms; Computers; Data acquisition; Imaging; Magnetic particles; Nickel; Real-time systems; Software;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Magnetic Particle Imaging (IWMPI), 2015 5th International Workshop on
  • Conference_Location
    Istanbul
  • Print_ISBN
    978-1-4799-7269-2
  • Type

    conf

  • DOI
    10.1109/IWMPI.2015.7107079
  • Filename
    7107079