DocumentCode :
7099
Title :
Successful Suppression of Pulse Shortening in an X -Band Overmoded Relativistic Backward-Wave Oscillator With Pure math\\rm{TM</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Author : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>Jun Zhang ; Zhenxing Jin ; Jianhua Yang ; Dian Zhang ; Ting Shu ; Jiande Zhang ; Huihuang Zhong</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Author_Institution : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>Coll. of Optoelectric Sci. & Eng., Nat. Univ. of Defense Technol., Changsha, China</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Volume : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>43</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Issue : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>2</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>fYear : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>2015</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>fDate : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>Feb. 2015</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Firstpage : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>528</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Lastpage : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>531</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Abstract : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>Long-pulse operation of relativistic backward-wave oscillators (RBWOs) is seriously handicapped by pulseshortening phenomenon. Explosive emission plasma formed on the surface of slow-wave structures (SWSs) due to RF breakdown is considered to be the predominant cause of pulse shortening in RBWOs. Utilizing overmoded SWSs with large diameter is effective for decreasing the field strength on the surface of SWSs and the possibility of RF breakdown. However, multiple modes may be output simultaneously in overmoded RBWOs. In this paper, both the power capacity and output mode purity of an X-band overmoded RBWO are substantially improved through optimizing the profile of the SWSs and geometric parameters of the whole electrodynamic structures. As a result, we successfully suppress pulse shortening and achieve pure TM<sub>01</sub> mode output simultaneously. The first ever reported experimental result is that the pure TM<sub>01</sub> mode is radiated with a power of 2 GW, a pulse duration of 116 ns, a power efficiency of 28%, and a repetition rate of 30 Hz.</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Keywords : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>backward wave oscillators; slow wave structures; RBWO; RF breakdown; SWS; X-band overmoded relativistic backward-wave oscillator; efficiency 28 percent; electrodynamic structure; explosive emission plasma; field strength; long-pulse operation; output mode purity; power 2 GW; power capacity; power efficiency; pulse duration; pulse shortening suppression; pure TM<sub>01</sub> mode output; repetition rate; slow-wave structure; Microwave devices; Microwave measurement; Microwave oscillators; Plasmas; Power generation; Radio frequency; High-power microwave (HPM) sources; long pulse; mode purity; pulse shortening; relativistic backward-wave oscillator (RBWO); relativistic backward-wave oscillator (RBWO).;</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>fLanguage : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>English</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Journal_Title : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>Plasma Science, IEEE Transactions on</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Publisher : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>ieee</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>ISSN : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>0093-3813</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Type : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>jour</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>DOI : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>10.1109/TPS.2014.2373037</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Filename : </div><div class='valueDiv leftDirection leftAlign col-xs-8 col-sm-10 fullRecValueEnglish'>7004082</div>
        </div>
        <div class='row'>
            <div class='leftDiv labelDiv col-xs-4 col-sm-2 fullRecLabelEnglish'>Link To Document : </div><div class='valueDiv leftDirection leftAlign fullRecValueEnglish col-xs-8 col-sm-10'><a href='https://search.ricest.ac.ir/dl/search/defaultta.aspx?DTC=49&DC=7099' target='_blank'>https://search.ricest.ac.ir/dl/search/defaultta.aspx?DTC=49&DC=7099</a></div>
        </div>
	    </div>
      <div class='leftDiv labelDiv leftAlign backLinkEnglish'><a href='javascript:history.back()'><img src='../CSS/Back.png' class='backImage' alt=