DocumentCode :
70992
Title :
A Three-Phase Power Flow Approach for Integrated 3-Wire MV and 4-Wire Multigrounded LV Networks With Rooftop Solar PV
Author :
Alam, M.J.E. ; Muttaqi, Kashem M. ; Sutanto, Danny
Author_Institution :
Endeavour Energy Power Quality & Reliability Res. Centre, Univ. of Wollongong, Wollongong, NSW, Australia
Volume :
28
Issue :
2
fYear :
2013
fDate :
May-13
Firstpage :
1728
Lastpage :
1737
Abstract :
With increasing level of rooftop solar photovoltaic (PV) penetration into low voltage (LV) distribution networks, analysis with realistic network models is necessary for adequate capturing of network behavior. Traditional three-phase 3-wire power flow approach lacks the capability of exact analysis of 4-wire multigrounded LV networks due to the approximation of merging the neutral wire admittance into the phase wire admittances. Such an approximation may not be desirable when neutral wire and grounding effects need to be assessed, especially in the presence of single-phase solar power injection that may cause a significant level of network unbalance. This paper proposes a three-phase power flow approach for distribution networks while preserving the original 3-wire and 4-wire configurations for more accurate estimation of rooftop PV impacts on different phases and neutrals. A three-phase transformer model is developed to interface between the 3-wire medium voltage (MV) and the 4-wire LV networks. Also an integrated network model is developed for an explicit representation of different phases, neutral wires and groundings of a distribution system. A series of power flow calculations have been performed using the proposed approach to investigate the impacts of single-phase variable PV generation on an Australian distribution system and results are presented.
Keywords :
distribution networks; earthing; load flow; photovoltaic power systems; power transformers; solar power; 4-wire multigrounded LV networks; Australian distribution system; grounding effects; groundings; integrated 3-wire MV networks; low voltage distribution networks; network unbalance; neutral wire admittance; phase wire admittances; rooftop PV impacts; rooftop solar photovoltaic penetration; single-phase solar power injection; three-phase 3-wire power flow; three-phase transformer; Admittance; Grounding; Inverters; Load modeling; Mathematical model; Vectors; Wires; 3-wire and 4-wire multigrounded systems; Rooftop solar PV impacts; three-phase distribution networks; three-phase power flow;
fLanguage :
English
Journal_Title :
Power Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8950
Type :
jour
DOI :
10.1109/TPWRS.2012.2222940
Filename :
6355704
Link To Document :
بازگشت