  • Abstract
    Multilevel converter topologies are widely used in applications of wide-power range. The T-type topology, which is one of many three-level topologies, has an advantage in terms of efficiency compared to the neutral-point-clamped (NPC) type. In applications using the T-type topology, interest in reliability has been increased recently. Therefore, the open-switch fault detection method and tolerance control for T-type rectifiers, which are different from those of T-type inverters, are necessary to improve the reliability of applications. When the open-switch fault of switches connected to a neutral point occurs, an NPC-type rectifier cannot restore distorted input currents; however, a T-type rectifier is able to eliminate input current distortion completely. In this paper, an open-switch fault detection method is proposed and can find a position of the open-switch fault. Moreover, two tolerance controls based on space vector modulation are proposed and their characteristics are analyzed. The effectiveness and performance of the proposed open-switch fault detection method and two tolerance controls are verified by simulations and experiments.
  • Keywords
    PWM invertors; PWM power convertors; PWM rectifiers; fault diagnosis; network topology; power factor; power grids; switches; NPC-type rectifier; SVM; T-type inverters; T-type topology; current distortion elimination; grid-connected T-type rectifier; multilevel converter topologies; neutral-point-clamped type rectifier; open-switch fault detection method; space vector modulation; three-level topologies; tolerance control; unity power factor; Circuit faults; Fault detection; Fault tolerance; Inverters; Rectifiers; Space vector pulse width modulation; Topology; Fault diagnosis; T-type rectifier; open-switch fault; tolerance control;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/TIE.2014.2316228
  • Filename
    6786015