• DocumentCode
    717354
  • Title

    Sensitivity analysis of the specific consumption of chemical energy of fuels for assumed uncertainty of selected measurements in a steam combined heat and power unit

  • Author

    Szega, Marcin ; Rusinowski, Henryk

  • Author_Institution
    Inst. of Thermal Technol., Silesian Univ. of Technol., Gliwice, Poland
  • fYear
    2015
  • fDate
    27-30 May 2015
  • Firstpage
    526
  • Lastpage
    531
  • Abstract
    The increase of measurement data reliability by the data reconciliation method is today an indispensable process in modern control systems of the operation of thermal installations. The results of measurements involve errors which are transmitted to errors of unknown values determined by means of mass and energy balance equations. Experiences from operation of the thermal systems show that assumed for data reconciliation calculations value of measurement uncertainty has significant influence on validation of the results of measurements and calculated values of indicators characterizing the operating conditions. The paper presents an analysis of the influence of the assumed measurement uncertainty on the results of the data reconciliation calculations and value of the specific consumption of chemical energy of fuels in the selected steam combined heat and power unit. Multivariate calculations for different values of assumed uncertainty of measurements and simulated limiting errors of measurements error were carried out. The results of these calculations to determine the sensitivity of the assumed measurements uncertainty on the specific consumption of chemical energy of fuels in the analyzed combined heat and power unit have been used.
  • Keywords
    cogeneration; energy consumption; measurement uncertainty; sensitivity analysis; chemical energy consumption; control systems; data reconciliation method; energy balance equation; fuels; mass balance equation; measurement data reliability; measurement uncertainty; multivariate calculations; sensitivity analysis; steam combined heat and power unit; thermal installations; thermal systems; Atmospheric measurements; Chemicals; Energy measurement; Heating; Measurement uncertainty; Particle measurements; Thermal analysis; data reconciliation method; measurement uncertainty; sensitivity analysis; steam combined heat and power unit;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Carpathian Control Conference (ICCC), 2015 16th International
  • Conference_Location
    Szilvasvarad
  • Print_ISBN
    978-1-4799-7369-9
  • Type

    conf

  • DOI
    10.1109/CarpathianCC.2015.7145136
  • Filename
    7145136