DocumentCode :
719741
Title :
Frequency response model considering large frequency deviation
Author :
Yuzheng Xie ; Hengxu Zhang ; Huadong Sun ; Shiyun Xu
Author_Institution :
Key Lab. of Power Syst. Intell. Dispatch & Control, Shandong Univ., Jinan, China
fYear :
2015
fDate :
28-30 May 2015
Firstpage :
940
Lastpage :
943
Abstract :
Large frequency deviation affects the output of auxiliary equipment of thermal power plant, which in turn will impact the operational security and stability of thermal power plant. This paper focuses on analyzing the relationship between out power and frequency of auxiliary equipment. The actual operating data is the base of determining the relation between system frequency and the output of feed pump. The input of coal is determined by the output of feed pump. Simulation models considering boiler and auxiliary equipment are built by simplifying the major equipment of thermal power plants. Numerical simulation systems are developed with MATALAB. The 300MW generation unit is adopted as the case for simulation analysis to illustrate how the frequency deviation impact generator output. Numerical simulations demonstrate the effectiveness of the proposed model.
Keywords :
boilers; frequency response; thermal power stations; auxiliary equipment; boiler; feed pump output; frequency deviation; frequency response model; generation unit; large frequency deviation; system frequency; thermal power plant; Coal; Load modeling; Numerical models; Sun; Time-frequency analysis; auxiliary equipment; feed pump; frequency deviation; simulation model;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Instrumentation and Control (ICIC), 2015 International Conference on
Conference_Location :
Pune
Type :
conf
DOI :
10.1109/IIC.2015.7150879
Filename :
7150879
Link To Document :
بازگشت