  • Abstract
    The concern for human welfare has caused the strong needs for a rapid, continuous, non-invasive sensor system of vital signs. Especially non-invasive and non-restraining systems are required, because they could monitor health status over a prolonged period. We have applied Fiber Bragg Grating (FBG) sensor to measure the vital signs. FBG could measure human pulse waves. Furthermore, based on the pulse waves, pulse rate and respiratory rate could be measured continuously and non-invasively. This paper describes the measurement method of Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP) by single FBG sensor. The pulse wave could be easily measured by FBG sensor at the right wrist and right elbow. The Partial Least Squares Regression (PLSR) has carried out by using the pulse waves and reference BP values. This paper also describes the adequate calibration model to measure the BP. It could satisfy the international standard that has been set for sphygmomanometric method.
  • Keywords
    Bragg gratings; biomedical equipment; blood pressure measurement; calibration; fibre optic sensors; least squares approximations; pneumodynamics; regression analysis; standards; DBP measurement; PLSR; SBP measurement; calibration model; continuous pulse rate measurement; continuous respiratory rate measurement; continuous vital sign sensor system; diastolic blood pressure; fiber Bragg grating sensor; health status monitoring; human pulse wave measurement; international standard; noninvasive blood pressure measurement; noninvasive pulse rate measurement; noninvasive respiratory rate measurement; noninvasive vital sign sensor system; nonrestraining system; partial least squares regression; rapid vital sign sensor system; reference BP value; single FBG sensor; sphygmomanometric method; systolic blood pressure; vital sign measurement; Biomedical measurement; Calibration; Fiber gratings; Pulse measurements; Temperature measurement; Wrist; Blood-Pressure; Fiber Bragg Grating; Non-invasive measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference (I2MTC), 2015 IEEE International
  • Conference_Location
    Pisa
  • Type

    conf

  • DOI
    10.1109/I2MTC.2015.7151320
  • Filename
    7151320