Title :
Perspectives in electric energy metrology
Author :
Abbas, Mohammed ; Al-Hadhrami, Luai M. ; Vaqar, Sayyid Anas
Author_Institution :
Res. Inst., King Fahd Univ. of Pet. & Miner. (KFUPM), Dhahran, Saudi Arabia
Abstract :
The actual conditions prevailing at outdoor (desert) electronic metering sites were profiled through in-situ measurements of meter surface temperatures and heat flows. The mapped field conditions were then simulated in a meter testing laboratory and accuracy tests performed on transformer-operated electronic meters. Analysis of the test data reveals the deleterious effect of high ambient temperatures on the measurement accuracy and precision of electronic meter indications. Based on the study results, measures are recommended to address concerns about the reliability/accuracy of energy measurement in uncontrolled desert environmental conditions.
Keywords :
energy measurement; power meters; electric energy metrology; electronic metering sites; energy measurement; heat flows; meter surface temperatures; transformer-operated electronic meters; Accuracy; Energy measurement; Heating; IEC standards; Temperature; Temperature measurement; Accuracy; Electronic Meter; Energy Measurement; Metering Standards; Metrology; Precision; Specifications;
Conference_Titel :
Instrumentation and Measurement Technology Conference (I2MTC), 2015 IEEE International
Conference_Location :
Pisa
DOI :
10.1109/I2MTC.2015.7151451