DocumentCode :
721552
Title :
Influences of turbo-generator end winding dimensions on electromagnetic loss in the end core and metal parts
Author :
Wang, L. ; Li, J. ; Li, W.
Author_Institution :
Harbin Univ. of Sci. & Technol., Harbin, China
fYear :
2015
fDate :
11-15 May 2015
Firstpage :
1
Lastpage :
1
Abstract :
For the complex structure of the large capacity turbo-generator in end region, the accurate calculation of the leakage magnetic field became key factor in large generator design. Affected by the leakage magnetic field, there is a problem that the end stator ladder packets, copper screen, press plate has a local high temperature. The three-dimensional electromagnetic field of a 330 MW water-hydrogen-hydrogen turbo-generator in the end region was investigated, and the effect of 4 stator ladder packets was considered in the calculation process. The influences of the end extension of stator and rotor end windings beyond the stator or rotor end 10cm on the losses of the end stator ladder packets, copper screen, and press plate were compared and analyzed. All of these will be help for the turbo-generator engineering design.
Keywords :
cores; rotors; stators; turbogenerators; 3D electromagnetic field; copper screen; electromagnetic loss; end stator ladder packet losses; large capacity turbogenerator; leakage magnetic field calculation; local temperature; power 330 MW; press plate; rotor end winding; stator end winding; stator ladder packet effect; turbogenerator end winding dimensions; turbogenerator engineering design; water-hydrogen-hydrogen turbogenerator; Generators; Iron; Magnetic fields; Rotors; Stator windings; Windings; eddy-current losses; electromagnetic field; end windings; iron losses; turbo-generator;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Magnetics Conference (INTERMAG), 2015 IEEE
Conference_Location :
Beijing
Print_ISBN :
978-1-4799-7321-7
Type :
conf
DOI :
10.1109/INTMAG.2015.7156690
Filename :
7156690
Link To Document :
بازگشت