Title : 
Basic consideration of winding arrangement of amorphous transformers for MW-class DC-DC converters
         
        
            Author : 
Tanaka, H. ; Nakamura, K. ; Ichinokura, O.
         
        
            Author_Institution : 
Tohoku Univ., Sendai, Japan
         
        
        
        
        
        
            Abstract : 
An interleaved winding arrangement is examined in this article for use in MW-class DC-DC converters. The frequency dependences of winding resistance of interleaved and non-interleaved winding arrangements are compared experimentally using a 10-kW test amorphous transformer. It is demonstrated that copper loss of non-interleaved winding significantly increases although the operating frequency is below 1 kHz. Hence, the MW-class amorphous transformer requires an interleaved winding to reduce copper loss.
         
        
            Keywords : 
DC-DC power convertors; power transformers; transformer windings; DC-DC converters; amorphous transformers; copper loss; frequency dependences; interleaved winding arrangement; power 10 kW; winding resistance; Copper; DC-DC power converters; Electrical resistance measurement; Frequency dependence; Resistance; Transformer cores; Windings;
         
        
        
        
            Conference_Titel : 
Magnetics Conference (INTERMAG), 2015 IEEE
         
        
            Conference_Location : 
Beijing
         
        
            Print_ISBN : 
978-1-4799-7321-7
         
        
        
            DOI : 
10.1109/INTMAG.2015.7157291