Abstract :
For precise operation of various applications such as vehicles, factory automation, robotics and aerospace, the need of motors are widely used. In particular, Brushless direct-current (BLDC) motors are currently preferred because of advantages which is miniaturization, high torque density and high efficiency in comparison to dc motors and induction motors. These motors should be considered for high stability and high reliability on faults which can seriously threaten the safety of operation.
Keywords :
brushless DC motors; fault diagnosis; stators; BLDC motor; asymmetric magnetic fields; brushless direct-current motors; reliability; stator interturn fault detection; third harmonic components; torque density; Brushless DC motors; Harmonic analysis; Induction motors; Magnetic fields; Permanent magnet motors;