DocumentCode :
722392
Title :
Measurement of hysteresis loop at the tip of the teeth of an inverter-driven squirrel-cage induction motor
Author :
Saito, K. ; Sasayama, T. ; Nakano, M.
Author_Institution :
KUBOTA Corp., Osaka, Japan
fYear :
2015
fDate :
11-15 May 2015
Firstpage :
1
Lastpage :
1
Abstract :
This study presents measurements of magnetic flux and hysteresis loops in a squirrel-cage induction motor using search coils located on the tip of the teeth. Results show maximum magnetic flux near the teeth which is decreased when the motor has the rated load. This is due to armature reaction caused by the current in the rotor conductor. Hysteresis loop results indicate that the iron loss beneath the teeth increases when the motor has a load.
Keywords :
magnetic flux; magnetic hysteresis; magnetic leakage; rotors; squirrel cage motors; armature reaction; hysteresis loops; inverter-driven squirrel-cage induction motor; iron loss; magnetic flux; rotor conductor; search coils; Coils; Hysteresis motors; Induction motors; Inverters; Magnetic flux; Magnetic hysteresis; Pulse width modulation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Magnetics Conference (INTERMAG), 2015 IEEE
Conference_Location :
Beijing
Print_ISBN :
978-1-4799-7321-7
Type :
conf
DOI :
10.1109/INTMAG.2015.7157771
Filename :
7157771
Link To Document :
بازگشت