Title :
Assessing blood pressure unobtrusively by smart chair
Author :
Zazula, D. ; Kranjec, J. ; Kranjec, P. ; Cigale, B.
Author_Institution :
Fac. of Electr. Eng. & Comput. Sci., Univ. of Maribor, Maribor, Slovenia
Abstract :
We developed a smart chair with unobtrusive sensors that measure functional-health parameters of a person sitting on the chair. Capacitive sensors are placed in the chair´s backrest and seat, while the armrests support a combination of U-shaped electrodes and incorporated photoplethysmographic (PPG) sensors for synchronous electrocardiographic (ECG) and PPG measurements. In a set of experiments with 11 young males, the two types of signals were acquired. Time distances were estimated between the ECG R-wave peaks and the PPG foots as detected by our heartbeat search, yielding the so called pulse transit times (PTTs). The experiments were conducted in two phases: the first one at rest and the second one after a minute of intensive squats. Referential systolic and diastolic blood pressures were taken just before every trial by a Critikon Dinamap Pro 300 sphygmomanometric device. Our goal was to model the relationship between blood pressure and estimated PTTs in both experimental phases. The obtained linear models revealed an interesting observation. Subjects reacted in two different physiological ways; 6 out of 11 participants conformed to a different model as the other 5 did. The main difference is the rate of decrease of either systolic or diastolic pressure per 1-ms change of the PTT.
Keywords :
biomedical electrodes; blood pressure measurement; capacitive sensors; electrocardiography; haemodynamics; medical signal detection; medical signal processing; photoplethysmography; Critikon Dinamap Pro 300 sphygmomanometric device; ECG; ECG R-wave peaks; PPG; PTT; U-shaped electrodes; capacitive sensors; diastolic blood pressures; functional-health parameters; heartbeat search; linear models; photoplethysmographic sensors; pulse transit times; smart chair; synchronous electrocardiographic measurements; systolic blood pressures; unobtrusive sensors; Biomedical monitoring; Blood pressure; Electrocardiography; Heart beat; Pressure measurement; Sensors; Blood pressure; Electrocardiogram; Photoplethysmogram; Pulse transit times; Smart chair; Unobtrusive sensing;
Conference_Titel :
Information and Communication Technology, Electronics and Microelectronics (MIPRO), 2015 38th International Convention on
Conference_Location :
Opatija
DOI :
10.1109/MIPRO.2015.7160300